Cat® CBS – ATS with Bypass Isolation (Spec Grade)

Cat® CBS – ATS with Bypass Isolation (Spec Grade)

Cat® CBS – ATS with Bypass Isolation (Spec Grade)

The CBS Series – Open Transition, Delayed Transition (CBSD), Closed Transition (CBSCT), ATS with Bypass Isolationis is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.

The CBS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health. Fast switching and no line voltages connected at the door provide advanced safety.

Technical Summary
Rating Range
100 - 3000 A
Transfer Type
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type
Contactor
System Information
Product nodes
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Rated Voltage and Frequency
200-480VAC, 50/60 Hz
Phase system
Single and Three
Number of poles
2, 3 and 4
Neutral configuration
Solid neutral, Switched neutral, Overlapping neutral (100-1200A only)
Product type
Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II)

Standard Equipment:

Control
  • Color touchscreen
  • Voltage and frequency settings: Pick up and Drop out
  • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
  • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
 
Additional Features
  • LED indications for ATS, S1 and S2 status
  • Programmable digital inputs/outputs
  • Auto config (voltage, frequency, phase system)
  • Source priority (Source 1/2, No priority)
  • Manual re-transfer
  • In-phase monitor (synchro check)
  • Genset exercising: on-load, off-load
  • In-built power meter module
  • Load shedding
  • Real time clock
  • Event log
  • Predictive maintenance
  • Voltage and current harmonics measuring
 
Accessories
  • Auxiliary contacts for position indication
  • Digital input/output modules (factory programmed)
  • 12-24 VDC aux supply module for controller
  • Communication modules
 
Connectivity Capability
  • Modbus RTU (RS-485)
  • Modbus/TCP
  • Profibus DP
  • ProfiNet Yes
  • DeviceNet
  • Ethernet IP
 
Applications
  • Utility - Utility
  • Utility - Generator
 
Ul Short Circuit Withstand Ratings
  • Coordinated breaker WCR
  • Time-based WCR
  • Short-time ratings
 

Optional Equipment:

Options
  • Options not available
 

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.